Product overview
Our Hospital Power Backup Diesel Generator delivers compliant, ultra-reliable emergency power with rapid automatic startup, ensuring uninterrupted operation for critical medical equipment and full adherence to healthcare safety regulations.
Critical Healthcare Engineering
NFPA 110 Type 10 Compliance Engineered to restore full stable load within 10 seconds of utility grid failure.
Total Harmonic Distortion <5% Clean electrical output prevents voltage fluctuations from damaging sensitive medical imaging systems.
Seismic and Wind Rated Enclosures are structurally certified to withstand regional earthquakes and high-velocity hurricane zones.
Hospital-Grade Acoustic Attenuation Multi-stage silencers reduce operational noise to 65 dB(A) at 7 meters for patient comfort.
Redundant Controller Configuration Dual-redundant AMF modules prevent single-point failures during critical emergency power transfers.
Technical Specifications & Generator Models
|
Parameter Category |
Specific Technical Parameter |
Standard Value / Specification |
Measurement Protocol |
|
Electrical Performance |
Transient Voltage Deviation |
≤ ±15% (100% single-step load) |
ISO 8528-5 Class G3 |
|
Voltage Recovery Time |
≤ 1.0 second |
IEC 60034-1 |
|
|
Total Harmonic Distortion (THD) |
< 2% linear / < 5% non-linear |
EN 61000-6-4 |
|
|
Telephone Influence Factor (TIF) |
< 50 |
NEMA MG1-32 |
|
|
Power Factor |
0.8 lagging |
Standard rating |
|
|
Engine & Propulsion |
Aspiration |
Turbocharged / Aftercooled |
Manufacturer standard |
|
Governor Type |
Electronic Isochronous |
ISO 8528 G3 |
|
|
Displacement |
15.8 L to 49.0 L |
Model dependent |
|
|
Compression Ratio |
16.5:1 |
Heavy-duty diesel standard |
|
|
Bore & Stroke |
135 × 150 mm (base model) |
Mechanical blueprint |
|
|
Fluid & Thermal |
Total Coolant Capacity |
95 L to 210 L |
Radiator integrated |
|
Total Lube Oil Capacity |
45 L to 135 L |
Pan capacity |
|
|
Exhaust Gas Temperature |
495°C |
Rated standby output |
|
|
Exhaust Gas Flow |
185 m³/min |
100% load rating |
|
|
Combustion Air Flow |
65 m³/min |
Intake requirement |
|
|
Structure & Safety |
Fuel Tank Capacity |
24-hour continuous runtime |
NFPA 110 requirement |
|
Base Frame Type |
Double-walled bunded tank |
Environmental EPA standard |
|
|
Lifting Points |
4-point overhead lift points |
ISO 8528 enclosure |
|
|
Circuit Breaker Type |
3-Pole MCCB / 4-Pole ACB optional |
IEC 60947-2 |
|
Model |
Standby Power |
Prime Power |
Engine Brand |
Fuel Consumption (100% Load) |
Dimensions (L × W × H mm) |
|
HDP-400 |
400 kVA / 320 kW |
360 kVA / 288 kW |
Baudouin |
82.4 L/h |
4200 × 1460 × 2150 |
|
HDP-650 |
650 kVA / 520 kW |
600 kVA / 480 kW |
Scania |
126.1 L/h |
4800 × 1650 × 2250 |
|
HDP-1000 |
1000 kVA / 800 kW |
900 kVA / 720 kW |
Mitsubishi |
198.5 L/h |
5300 × 2100 × 2550 |
|
HDP-1650 |
1650 kVA / 1320 kW |
1500 kVA / 1200 kW |
Baudouin |
310.2 L/h |
6200 × 2300 × 2800 |
|
HDP-2250 |
2250 kVA / 1800 kW |
2000 kVA / 1600 kW |
Mitsubishi |
425.7 L/h |
7800 × 2450 × 3100 |
Manufacturing & Quality Control
100% Load Bank Testing:
Every generator undergoes 0%, 25%, 50%, 75%, 100%, and 110% load step testing before factory dispatch.
10-Second Black-Start Verification:
Transient response testing ensures automated power delivery within the mandatory 10-second NFPA 110 threshold.
3-Hour Continuous Endurance Run:
Each critical care unit undergoes a 3-hour unbroken thermal stability test under full load.
Micro-Ohm Alternator Resistance Test:
Digital micro-ohmmeters verify winding resistance limits to guarantee low harmonic distortion rates (<5%).
Acoustic Decibel Mapping:
Calibrated sound-level meters verify enclosure insulation achieves <65 dB(A) at 7 meters.
Regulatory Standards & Compliance
|
Standard / Certification |
Target System / Compliance Area |
Verified Verification Threshold |
|
UL 2200 |
Stationary Engine Generator Assemblies |
Certified safety for complete stationary package |
|
EPA Tier 4 / Stage V |
Exhaust After-Treatment Systems |
Low-emission compliance for hospital environments |
|
ISO 8528-5 Class G3 |
Governing & Transient Response |
High-precision voltage and frequency stability |
|
IEC 60364-7-710 |
Electrical Isolation & Grounding |
Medical Group 2 electrical safety compliance |
|
CE Mark |
Switchgear & Control Systems |
Compliance with European low-voltage and EMC directives |
Technical Consultation & Support
SLD Alignment Support
Factory application engineers verify Single Line Diagrams to ensure seamless onsite switchgear integration.
Sizing Analysis Report
We calculate peak motor-starting currents to determine precise engine kVA capacity requirements.
Fuel System Engineering
Technical drawing reviews configure external auxiliary fuel supply lines and remote pumping infrastructure.
ATS Controls Integration
Engineering support matches custom PLC programming with existing building management systems (BMS).
FAQ